- Pi datalink 2013 install kit password#
- Pi datalink 2013 install kit download#
- Pi datalink 2013 install kit windows#
You can spell out month and weekday names, or enter the first three letters (for example, Yes yes yes w wd yd weeks weekdays yeardays no yes (for example, Tuesday) no no no no S seconds no m h minutes hours no no d mo y days months years no no yes (for example, December) no no no Second minute hour day month year week weekday yearday For intervals where the Fractions column indicates No, fractional amounts cannot be used in time strings. Intervals that support fractional values are listed below. PI Time abbreviations and PI Time expressions allow you to specify times and time ranges for data using constants, variables, and short expressions.Īn interval is a unit of time that can be used in time entries. For this reason, System Administrators should not normally allow PIĭataLink users to log in as PIAdmin. Note: The PIAdmin account is a super-privileged user and has read and write access to all tags. O:RW (read and write) to enable a user logging in as user1 to read and write data to sinusoid. The PI System Manager would need to change DataAccess to However, the same user may not write data to sinusoid because the DataAccess attribute is O:R (read only).

Otherwise, a read access error message is returned. If sinusoid DataAccess is O:R, G:NONE, W:NONE, and DataOwner is user1, a user must log in as user1 in order to see sinusoid tag data. W:NONE, and PtOwner is user1, a user must log in as user1 in order to access the tag. The username is used in conjunction with the PtOwner, PtAccess, DataOwner, andįor example, if the sinusoid tag is configured with PtAccess O:RW, G:NONE,
Pi datalink 2013 install kit password#
PI DataLink prompts the user for a username and password upon connection to a PI server. PI trusts are established on the PI server and stored in a trust database.
Pi datalink 2013 install kit windows#
A trust may instead allow a user to log in based on an IP address, Windows domain, user name, application or other criteria. *.*.*.*, DISALLOW 192.168.100.*, ALLOW allows connections only from TCP/IP addresses starting with 192.168.100.Ī PI trust allows clients to connect to a PI server machine and retrieve data without explicit user login. PIConfig> hostmask=* PIconfig> *.*.*.*, ALLOW blocks no IP ranges, indicating that all client machines may connect to PI 3 Server. PIConfig> pi_gen,pifirewall PIConfig> hostmask,value The firewall database on a PI server machine must be configured to allow access from client computers running PI DataLink.
Pi datalink 2013 install kit download#
PI Server ConnectivityĬlient computers running Microsoft Excel and PI DataLink can retrieve data from PI 3 servers.įor more information on PI Server connectivity and security, consult your PI Server documentation, or download documentation from the OSIsoft technical support site See Connection Preferences in the High Availability Advanced User Guide for an explanation of connectivity preferences.

If the first connection is made with the trend control, tag search, or the connection manager, then the connection preference is set to Prefer Primary. Supplementary Information functions, then it makes a connection with connection preference of Any. If the first connection is made with DataLink However, since the connection preference is set at the time of the connection, the order in which the connection is made matters. The connection preference is set at the time of the first connection.įor DataLink 3.1.6 and above, the connection preference for DataLink functions is set toĪny. See the PI SDK setup.ini for further information and descriptions of available arguments. You can make site-specific alterations to the file as needed. Silent Installsįor silent installs, use the silent.ini file provided in the PI DataLink distribution kit by typing: If you have Excel 2007 on your PC, the install program automatically configures the addin for Excel 2007. If you have Excel XP-2003 on your PC, you must configure the add-in manually (page 4)Īfter installation by adding it to Excel.

The installation program automatically installs both Excel XP-20 versions of the PI DataLink add-in to your system, regardless of which version of Excel you have installed. You can install PI DataLink from a distribution CD or an installation kit downloaded from Note: Previous versions of PI DataLink allowed a shared version to be installed and run from a central file server. Web users may view spreadsheets with PI DataLink functions using PI DataLink ServerĬontact your OSIsoft sales representative for more information. Users can install a stand-alone version of PI DataLink on their local PC. There are two ways for users to work with PI DataLink functions in Excel spreadsheets: Appendix A Supplementary Information Setup